Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38553310

RESUMEN

OBJECTIVE: This study aimed to assess the performance of a convolutional neural network (CNN) model in detecting the pubertal growth spurt by analyzing cervical vertebrae maturation (CVM) in lateral cephalometric radiographs (LCRs). STUDY DESIGN: In total, 600 LCRs of patients from 6 to 17 years old were selected. Three radiologists independently and blindly classified the maturation stages of the LCRs and defined the difficulty of each classification. Subsequently, the stage and level of difficulty were determined by consensus. LCRs were distributed between training, validation, and test datasets across 4 CNN-based models. The models' responses were compared with the radiologists' reference standard, and the architecture with the highest success rate was selected for evaluation. Models were developed using full and cropped LCRs with original and simplified maturation classifications. RESULTS: In the simplified classification, the Inception-v3 CNN yielded an accuracy of 74% and 75%, with recall and precision values of 61% and 62%, for full and cropped LCRs, respectively. It achieved 61% and 62% total success rates with full and cropped LCRs, respectively, reaching 72.7% for easy-to-classify cropped cases. CONCLUSION: Overall, the CNN model demonstrated potential for determining the maturation status regarding the pubertal growth spurt through images of the cervical vertebrae. It may be useful as an initial assessment tool or as an aid for optimizing the assessment and treatment decisions of the clinician.

2.
Odontology ; 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38214844

RESUMEN

This study aimed to evaluate the influence of the metal post composition, tooth location in the dental arch, and metal artifact reduction (MAR) on vertical root fracture (VRF) diagnosis in cone beam computed tomography (CBCT). Twenty-two unirradicular premolars (12 sound and 10 fractured) and two alveolar sockets of a mandible (anterior and posterior regions) composed the sample. CBCT scans of each tooth with a metal post placed into the root canal-silver-palladium (Ag-Pd), cobalt-chromium (Co-Cr), or nickel-chromium (Ni-Cr)-were individually acquired for each mandibular region, and two conditions of MAR, using a OP300 device (Instrumentarium, Finland). Images were assessed by five evaluators independently for VRF detection. Diagnostic values were calculated and compared among all groups using multi-way ANOVA with Tukey post hoc test to investigate the effect of post material, anatomical region, and MAR on VRF diagnosis (α = 0.05). Values of area under the receiver operating curve and specificity were not influenced by the studied factors (p > 0.05). Sensitivity was influenced by the MAR in both mandibular regions (p < 0.05). In the anterior region, sensitivity values increased when the MAR was enabled, regardless of the metal post material (p < 0.05). Similar behavior was noticed in the posterior region for Ni-Cr (p < 0.05) but not for Ag-Pd and Co-Cr posts (p > 0.05). The MAR improved the sensitivity in VRF diagnosis for all tested metal posts in the mandibular anterior region and for the Ni-Cr post in the mandibular posterior region. Therefore, for images obtained in the OP300 CBCT device, activation of the MAR is suggested in these cases.

3.
Artículo en Inglés | MEDLINE | ID: mdl-37940483

RESUMEN

OBJECTIVE: We evaluated the influence of an adjacent zirconium implant, tube current (mA), and a metal artifact reduction algorithm (MARA) on horizontal root fracture (HRF) diagnosis in cone beam computed tomography (CBCT). STUDY DESIGN: Nineteen teeth (9 with HRF, 10 without) were individually placed in a human maxilla. Scan volumes were acquired without and with a zirconium implant adjacent to the tooth at settings of 4, 8, and 10 mA, with MARA disabled and enabled, using a 5×5 cm field of view, 0.085-mm voxel size, and 90 kV. Four maxillofacial radiologists individually assessed the scans. Diagnostic metrics were compared by multiway analysis of variance (α=5%). Inter- and intraexaminer agreements for HRF diagnosis were evaluated with the weighted kappa test. RESULTS: Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were significantly lower in the presence of the implant (P≤.005). AUC values were higher in scans obtained with 8 and 10 mA compared with 4 mA (P=0.010), but 10 mA without MARA was better with the implant present. MARA did not significantly influence outcomes (P≥0.240). Inter- and intraexaminer agreements ranged from moderate to almost perfect. CONCLUSIONS: The presence of the zirconium implant impairs HRF detection. Settings of 8 or 10 mA improve HRF detection regardless MARA condition without the implant. With an adjacent implant, 10 mA without MARA is recommended to improve diagnostic performance.


Asunto(s)
Fracturas de los Dientes , Raíz del Diente , Humanos , Raíz del Diente/diagnóstico por imagen , Circonio , Fracturas de los Dientes/diagnóstico por imagen , Artefactos , Tomografía Computarizada de Haz Cónico/métodos , Algoritmos
4.
Artículo en Inglés | MEDLINE | ID: mdl-37838553

RESUMEN

OBJECTIVE: We evaluated artifact expression in a root adjacent to a dental implant located in the endomass or exomass in cone beam computed tomography (CBCT). STUDY DESIGN: We placed a single titanium or zirconia implant adjacent to a premolar root in a dried human mandible and acquired CBCT scans using an OP300 Maxio and a Picasso Trio 3D unit exposing a 5x5cm field of view with the implant in the endomass or exomass (implant groups) or without an implant (control group). We measured the mean gray values (MGVs) for 8 lines of interest (LOIs) around the root canal of the premolar and compared the MGVs by analysis of variance, with significance established at P < 0.05. RESULTS: For the OP300 Maxio scans, the MGVs of both implant groups in the endomass were lower than the MGVs of the control group. In the exomass, the titanium group had MGVs similar to the control group, but the zirconia group produced significantly lower MGVs than control and titanium groups (P <.0001), indicating the presence of hypodense artifacts. For the Picasso Trio 3D scans, the MGVs of both implant groups in the endomass were similar to the MGVs of the control group. In the exomass, the zirconia group generated lower MGVs than control and titanium groups (P <.0001), indicating hypodense artifacts. CONCLUSIONS: When performing CBCT examination, titanium implants produce less artifact expression in the exomass, and zirconia implants have less artifact expression in the endomass.


Asunto(s)
Implantes Dentales , Titanio , Humanos , Artefactos , Circonio , Tomografía Computarizada de Haz Cónico/métodos
5.
Braz Dent J ; 34(4): 150-157, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37909638

RESUMEN

This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Asunto(s)
Radiografía Dental Digital , Radiografía Dental Digital/métodos
6.
Clin Oral Investig ; 27(11): 6451-6460, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37728617

RESUMEN

OBJECTIVES: To compare the multilayer panoramic radiography (MPAN) and conventional panoramic radiography (CPAN) in the evaluation of mandibular third molars using cone-beam computed tomography (CBCT) as a reference. METHODS: CPAN, MPAN, and CBCT scans from 33 dry human mandibles were acquired using the OP300 Maxio unit, totalizing 56 mandibular third molars to be evaluated. Three examiners evaluated each third molar according to their position, depth of impaction in the mandibular ramus, proximity between the dental root apexes and the mandibular canal, and the presence of radiographic signs of proximity to the mandibular canal. In addition, when there was a distance between the root apexes and the mandibular canal, it was measured. As a reference, these same parameters were assessed in the CBCT scans by a fourth examiner. For the statistical analysis, the weighted Kappa, Bland Altman, and Wilcoxon tests were performed (α = 0.05). RESULTS: The agreement between the assessments performed in the panoramic modalities with the CBCT ranged from 66.1% to 100.0% for the categorical variables. Overall, the agreement values of CPAN and MPAN with CBCT were similar. The distances between the dental root apex and the mandibular canal for both CPAN and MPAN were significantly underestimated compared to CBCT (p < 0.05). The intra- and interexaminer agreements of the examiners ranged from poor to almost perfect; in general, the agreements were higher in the evaluation performed in the MPAN than in the CPAN. CONCLUSIONS: The MPAN performs similarly to CPAN for evaluating mandibular third molars and their proximity relationship to the mandibular canal. CLINICAL RELEVANCE: Preoperative evaluation of lower mandibular third molars is usually performed using CPAN. Recently, a new tool, MPAN, was developed, which has not yet been tested for the evaluation of mandibular third molars and showed similar performance to CPAN in the present study. Future studies using MPAN are encouraged to evaluate other diagnostic tasks.


Asunto(s)
Tercer Molar , Diente Impactado , Humanos , Tercer Molar/cirugía , Radiografía Panorámica/métodos , Diente Molar , Mandíbula , Tomografía Computarizada de Haz Cónico/métodos
7.
Braz. dent. j ; 34(4): 150-157, July-Aug. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1520332

RESUMEN

Abstract This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Resumo Este estudo teve como objetivo avaliar a influência do formato do arquivo nos parâmetros de qualidade de imagem (ruído de imagem, brilho e uniformidade) de radiografias periapicais adquiridas com diferentes sistemas digitais. As imagens radiográficas de um fantoma de acrílico foram adquiridas com dois sistemas digitais - Digora Toto e Express, e exportadas em cinco formatos de arquivo diferentes - TIFF, BMP, DICOM, PNG e JPEG. O ruído da imagem, o brilho da imagem (média dos valores de cinza) e a uniformidade da imagem (desvio padrão dos valores de cinza) foram avaliados em todas as imagens. A análise de variância (ANOVA) bidirecional com o teste post-hoc de Tukey foi aplicada para comparar os resultados, considerando os formatos de arquivo e os sistemas radiográficos como os fatores estudados. Um nível de significância de 5% foi adotado para todas as análises. O formato de arquivo de imagem DICOM apresentou menor ruído de imagem, maior brilho (maiores valores médios de cinza) e maior uniformidade de imagem (p<0,001) do que os outros formatos de arquivo, que não diferiram entre si para ambos os sistemas de radiografia digital (p>0,05). O sistema Express apresentou menor ruído de imagem e maior uniformidade de imagem que o sistema Digora Toto, independentemente do formato do arquivo de imagem (p<0,001). Além disso, o Express mostrou maior brilho do que o Digora Toto para todos os formatos de arquivo de imagem (p<0,001), exceto para o formato de arquivo de imagem DICOM, que não diferiu significativamente entre os sistemas de radiografia digital testados (p>0,05). O formato de arquivo de imagem DICOM mostrou menor ruído de imagem, maior brilho e maior uniformidade de imagem do que os outros formatos de arquivo (TIFF, BMP, PNG e JPEG) em ambos os sistemas de radiografia digital testados.

8.
Artículo en Inglés | MEDLINE | ID: mdl-37468380

RESUMEN

OBJECTIVE: This study evaluated changes in image quality and the presence and size of artifacts on radiographs obtained with photostimulable phosphor (PSP) plates after disinfection with 70% ethyl alcohol and 70% isopropyl alcohol. STUDY DESIGN: Eight PSP receptors (4 Express and 4 VistaScan) were used for the investigation. Two Express and 2 VistaScan receptors were disinfected with 70% ethyl alcohol, and 2 Express and 2 VistaScan receptors were disinfected with 70% isopropyl alcohol. Before disinfection and after every 5 disinfections, 2 radiographs of an aluminum stepwedge and 2 radiographs of an acrylic block were acquired using each receptor. The gray values of the radiographs were analyzed regarding contrast, density, uniformity, and noise. Four oral radiologists evaluated the images for the presence of artifacts, and 2 measured the artifacts. RESULTS: Differences in image contrast were significantly larger with isopropyl alcohol (P < .0001). Artifact size was significantly greater with the VistaScan system when isopropyl alcohol was used as the disinfectant (P < .0001). The correlation between the number of disinfections and artifact size was moderately positive with the Express system (P < .05) and strongly positive with the VistaScan system (P < .05) with both disinfectants. CONCLUSIONS: Small artifacts restricted to the edges of the image were observed with disinfection using both types of alcohol, and a positive correlation was found between artifact size and the number of disinfections. However, artifacts appeared earlier and of greater size with the VistaScan system when disinfected with 70% isopropyl alcohol. Thus, we recommend using 70% ethyl alcohol to disinfect PSP receptors, with attention placed on its action and evaporation times.


Asunto(s)
2-Propanol , Radiografía Dental Digital , Humanos , Radiografía Dental Digital/métodos , Desinfección/métodos , Artefactos , Intensificación de Imagen Radiográfica/métodos , Etanol
9.
Sci Rep ; 13(1): 6266, 2023 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-37069172

RESUMEN

Photon-counting computed tomography (PCCT) is an innovative technological advancement in relation to x-ray detectors which offers ultra-high-resolution images. The current study aimed to evaluate the visualization ability of PCCT compared to cone-beam computed tomographic (CBCT) devices for challenging endodontic diagnostic tasks. A reference image of an anthropomorphic phantom was acquired using an industrial micro-CT device. Thereafter, the phantom was scanned with three imaging devices, which included PCCT scanner (NAEOTOM Alpha) and two CBCT devices (3D Accuitomo 170 and NewTom VGi evo) having standard and high-resolution acquisition protocols. The diagnostic tasks involved visualizing fine endodontic structures (apical delta, narrow canal, and isthmus) and root cracks. Three experienced examiners assessed the images and were blinded to the PCCT and CBCT devices. Each image was rated according to a three-grade scale (appropriate, acceptable, or inappropriate) for the diagnostic tasks. In relation to fine endodontic structures grouped together, PCCT showed similar diagnostic performance compared to the reference image (p > 0.05). As for the CBCT devices, an excellent performance was only observed with the 3D Accuitomo 170 device at a high-resolution acquisition mode (p > 0.05). The visualization of root cracks was also better with 3D Accuitomo 170 compared to other devices (p < 0.05). Overall, PCCT and 3D Accuitomo 170 at a high-resolution setting showed similar performance for visualizing fine endodontic structures. In addition, the high-resolution CBCT protocol was superior for visualizing root cracks compared to both PCCT and other standard- and high-resolution CBCT protocols.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada de Haz Cónico/métodos , Estudios de Factibilidad , Microtomografía por Rayos X , Fantasmas de Imagen
10.
Artículo en Inglés | MEDLINE | ID: mdl-36566136

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the influence of the extensive use of a photostimulable phosphor (PSP) receptor on the diagnosis of proximal carious lesions. STUDY DESIGN: Forty posterior teeth were paired and mounted in 20 phantoms. Using a PSP receptor of the Express intraoral system, 1 radiograph of each phantom was acquired, totaling 20 radiographs (group 1). After 400 acquisitions, another radiograph of each phantom was obtained, totaling 20 new radiographs (group 2). This procedure was also done after 800 (group 3), 1,200 (group 4), and 1,600 (group 5) acquisitions, resulting in 100 radiographs. Another 40 radiographs (20 phantoms × 2 groups) were obtained with a second PSP sensor to evaluate the diagnostic replicability of the receptors. All 140 radiographs were assessed independently by 5 examiners for the presence of proximal caries. Area under the receiver operating characteristic curve, sensitivity, and specificity were calculated and compared among the groups by analysis of variance. The Student t test evaluated the diagnostic replicability of the receptors. The significance level was set at 5% (P < .05). RESULTS: The diagnostic outcomes for proximal caries did not differ among the groups (P ≥ .37). The diagnostic values did not differ among the radiographs acquired with the 2 PSP receptors (P ≥ .75). CONCLUSIONS: The diagnosis of proximal carious lesions was not affected by extensive use of the PSP receptor.


Asunto(s)
Caries Dental , Radiografía de Mordida Lateral , Humanos , Caries Dental/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Diente Molar/patología , Sensibilidad y Especificidad
11.
J Prosthet Dent ; 129(5): 741-747, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-34399992

RESUMEN

STATEMENT OF PROBLEM: Knowledge about the location and dimensions of the mental foramen is important for surgical planning and implant placement in the posterior mandibular region. PURPOSE: The purpose of this clinical study was to assess the location and dimensions of the mental foramen in individuals of different facial type, skeletal class, and sex by means of cone beam computed tomography (CBCT) images. MATERIAL AND METHODS: CBCT images of 142 individuals (72 women and 70 men) were classified according to the facial type (dolichocephalic, mesocephalic, or brachycephalic) and skeletal class (I, II, or III). The vertical and horizontal locations of each mental foramen were evaluated on panoramic reconstructions, and the greatest height and width of the mental foramen were determined on multiplanar reconstructions. Also, the distances from the mental foramen to the alveolar crest and to the inferior cortex of the mandible were obtained. The data were compared by using the Kruskal-Wallis test and multiway analysis of variance (α=.05). RESULTS: The facial type, skeletal class, and sex did not influence the vertical (P=1.00) or the horizontal (P>.15) location of the mental foramen. The most frequent location of the mental foramen was between the first and second premolars and below their apices. The dimensions of the mental foramen were not influenced by the studied factors in men (P>.07); conversely, the mental foramen dimensions were influenced for women (P<.03). CONCLUSIONS: The most frequent location of the mental foramen was between the first and second premolars and below their apices. An influence of the facial type and skeletal class was observed on the dimensions of the mental foramen in women.


Asunto(s)
Foramen Mental , Tomografía Computarizada de Haz Cónico Espiral , Masculino , Humanos , Femenino , Mandíbula/diagnóstico por imagen , Cara/diagnóstico por imagen , Proceso Alveolar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos
12.
Braz Dent J ; 33(1): 31-40, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35262552

RESUMEN

This study aimed to assess the effect of the MAR tool on the expression of artefacts in different regions of a tooth restored with different types of metal posts. Alveolar sockets (anterior, and posterior region) of a mandible and an unirradicular tooth were used. Cone beam computed tomography scans of the tooth without a metal post, and with cobalt-chromium (Co-Cr), nickel-chromium (Ni-Cr), or silver-palladium (Ag-Pd) were individually obtained, with 2 MAR conditions: disabled, and enabled. In an axial reconstruction, lines of interest (LOIs) were set around the canal: 4 in oblique (mesiobuccal, distobuccal, mesiolingual, distolingual) directions, and 4 in orthogonal (mesial, distal, buccal, lingual) directions. Beam-hardening artefacts expression was determined by calculating the difference in the mean of gray values (DMGV) between the experimental and control groups for each LOI. There was no significant difference in the DMGV values between "without MAR" and "with MAR" for any LOI, in neither anterior nor posterior mandible (p>0.05), for the Ni-Cr and Co-Cr groups. For the Ag-Pd, significant differences in the DMGV values were observed between "without MAR" and "with MAR" for most LOIs (p<0.05), mainly in oblique directions in the anterior region, and mesio-distal direction in the posterior region. MAR acted mostly in hypodense artefacts (negative DMGV). The effectiveness of the MAR tool of the OP300 CBCT unit varied according to the post material tested. It was effective in reducing the expression of artefacts raised by the Ag-Pd post, mainly in the tooth regions affected by hypodense artefacts, regardless of the mandibular region.


Asunto(s)
Artefactos , Tomografía Computarizada de Haz Cónico Espiral , Algoritmos , Tomografía Computarizada de Haz Cónico/métodos , Mandíbula/diagnóstico por imagen
13.
Braz. dent. j ; 33(1): 31-40, jan.-fev. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1364482

RESUMEN

Abstract This study aimed to assess the effect of the MAR tool on the expression of artefacts in different regions of a tooth restored with different types of metal posts. Alveolar sockets (anterior, and posterior region) of a mandible and an unirradicular tooth were used. Cone beam computed tomography scans of the tooth without a metal post, and with cobalt-chromium (Co-Cr), nickel-chromium (Ni-Cr), or silver-palladium (Ag-Pd) were individually obtained, with 2 MAR conditions: disabled, and enabled. In an axial reconstruction, lines of interest (LOIs) were set around the canal: 4 in oblique (mesiobuccal, distobuccal, mesiolingual, distolingual) directions, and 4 in orthogonal (mesial, distal, buccal, lingual) directions. Beam-hardening artefacts expression was determined by calculating the difference in the mean of gray values (DMGV) between the experimental and control groups for each LOI. There was no significant difference in the DMGV values between "without MAR" and "with MAR" for any LOI, in neither anterior nor posterior mandible (p>0.05), for the Ni-Cr and Co-Cr groups. For the Ag-Pd, significant differences in the DMGV values were observed between "without MAR" and "with MAR" for most LOIs (p<0.05), mainly in oblique directions in the anterior region, and mesio-distal direction in the posterior region. MAR acted mostly in hypodense artefacts (negative DMGV). The effectiveness of the MAR tool of the OP300 CBCT unit varied according to the post material tested. It was effective in reducing the expression of artefacts raised by the Ag-Pd post, mainly in the tooth regions affected by hypodense artefacts, regardless of the mandibular region.


Resumo O objetivo nesse estudo foi avaliar o efeito da ferramenta de redução de artefato (FRA) na expressão de artefatos em diferentes regiões de um dente restaurado com diferentes tipos de pinos metálicos. Foram usados ​​alvéolos (regiões anterior e posterior) de uma mandíbula e um dente unirradicular. Imagens de tomografia computadorizada de feixe cônico do dente sem pino metálico intracanal e com pinos de cobalto-cromo (Co-Cr), níquel-cromo (Ni-Cr) ou prata-paládio (Ag-Pd) foram individualmente obtidas, com 2 condições de FRA: desativada e ativada. Em uma reconstrução axial, linhas de interesse (LOIs) foram definidas ao redor do canal: 4 em direções oblíquas (mésio-vestibular, disto-vestibular, mésio-lingual e disto-lingual) e 4 em direções ortogonais (mesial, distal, vestibular e lingual). A expressão dos artefatos de endurecimento do feixe foi determinada pelo cálculo da diferença na média dos valores de cinza (DMVC) entre os grupos experimental e controle para cada LOI. Não houve diferença significativa nos valores de DMVC entre as condições "sem FRA" e "com FRA" para nenhuma das LOIs, nem na região anterior nem na região posterior da mandíbula (p>0,05), para os grupos Ni-Cr e Co-Cr. Para o Ag-Pd, diferenças significativas nos valores de DMVC foram observadas entre "sem FRA" e "com FRA" para a maioria das LOIs (p<0,05), principalmente nas direções oblíquas na região anterior, e na direção mesio-distal na região posterior. A FRA atuou principalmente em artefatos hipodensos (DMVC negativos). A eficácia da FRA disponível no aparelho de TCFC OP300 variou de acordo com o material do pino testado. Ela foi efetiva na redução da expressão de artefatos originados por pinos de Ag-Pd, principalmente nas regiões do dente afetadas por artefatos hipodensos, independentemente da região mandibular.

14.
Oral Radiol ; 38(4): 452-458, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34626307

RESUMEN

OBJECTIVE: To evaluate the influence of the file format of digital periapical radiographs on the diagnosis of vertical root fracture (VRF). STUDY DESIGN: Periapical radiographic images of 34 single-rooted teeth-19 with VRF, and 15 without VRF were acquired using two digital systems-Digora Toto, and Digora Optime, and exported into four different file formats-TIFF, BMP, PNG, and JPEG, totaling 272 radiographs. The radiographs were assessed by five examiners for the detection of VRF, using a 5-point scale (1-definitely absent; 2-probably absent; 3-uncertain; 4-probably present; 5-definitely present). Diagnostic values of area under the ROC curve, specificity, and sensitivity for the diagnosis of VRF were calculated. The results were compared by two-way Analysis of Variance with post hoc Tukey's test. The intra- and inter-examiner agreements were measured by the Kappa test. The significance level was set at 5% for all analyses. RESULTS: The values of intra-examiner agreement varied from moderate (0.56) to almost perfect (0.81), while the values of inter-examiner agreement varied from fair (0.29) to moderate (0.60). The image file format did not influence the diagnostic values for VRF for any of the radiographic systems tested (p > 0.05). Digora Toto had significantly greater values of area under the ROC curve than Digora Optime for all file formats (p = 0.001). CONCLUSION: The image file format of periapical radiographs does not influence the diagnosis of VRF, regardless of the digital radiography system.


Asunto(s)
Fracturas de los Dientes , Humanos , Compuestos de Quinolinio , Radiografía , Radiografía Dental Digital/métodos , Tiazoles , Fracturas de los Dientes/diagnóstico por imagen , Raíz del Diente/diagnóstico por imagen
15.
Clin Oral Investig ; 25(2): 571-579, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32772328

RESUMEN

OBJECTIVES: To objectively assess the expression and direction of artefacts in the vicinity of metal posts positioned in different mandibular regions. MATERIALS AND METHODS: A human mandible had two sockets prepared-anterior and posterior regions-to accommodate a single-rooted tooth. Two CBCT units, Picasso Trio and OP300, were used. CBCT images of the tooth without metal post, and with silver-palladium, nickel-chromium, or cobalt-chromium posts (experimental groups) were individually acquired. Then, 8 lines of interest (LOIs) were determined around the root canal, in an axial reconstruction: 4 in orthogonal (buccal, lingual, mesial, and distal) directions, and 4 in oblique (mesiobuccal, distobuccal, mesiolingual, and distolingual) directions. The mean of gray values was measured for each LOI. RESULTS: For the OP300, in general, all experimental groups showed greater expression of hyperdense streaks in orthogonal LOIs and greater expression of hypodense streaks in oblique LOIs. For the Picasso Trio, for both mandibular regions, the buccal LOI showed greater expression of hypodense streaks; conversely, greater expression of hyperdense streaks was observed in the distal and distobuccal LOIs in the anterior region and in the mesiolingual LOI in the posterior region. The silver-palladium group showed significantly greater expression of beam hardening artefacts in the posterior region of the mandible, regardless of the CBCT unit (p < 0.05). The mandibular posterior region showed significantly lower gray values than the anterior region (p < 0.05). CONCLUSION: The expression and direction of artefacts produced in the vicinity of metal posts vary according to the mandibular region, composition of the post, and CBCT unit. CLINICAL RELEVANCE: The mapping of artefacts produced by metal posts reveals the root regions with greater expression of hypodense and hyperdense artefacts, which may contribute to recognizing regions more likely to mimic or hide root fracture lines.


Asunto(s)
Artefactos , Tomografía Computarizada de Haz Cónico , Arco Dental , Cavidad Pulpar , Humanos , Mandíbula/diagnóstico por imagen , Raíz del Diente
16.
Clin Oral Investig ; 25(4): 2229-2235, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32827079

RESUMEN

AIM: To evaluate the influence of the tube current and metal artifact reduction (MAR) tool on the diagnosis of vertical root fractures (VRF) in a tooth adjacent to a zirconium implant, in cone-beam computed tomography (CBCT) images. METHODOLOGY: Thirty single-rooted teeth (15 with VRF and 15 control group) were individually positioned in a mandible, and scanned with the OP300 CBCT unit. Images were acquired using a standardized protocol: 5 × 5 cm field of view, 0.08-mm voxel size, and 90 kVp. Each tooth was scanned with and without a zirconium implant in its vicinity, using different tube currents (4 mA, 8 mA, and 10 mA) and conditions of MAR (enabled × disabled). Diagnostic values were calculated for each protocol, and compared by multi-way analysis of variance. RESULTS: The ROC curve and sensitivity values did not differ significantly among the tube currents, regardless of the presence of the implant and MAR condition (p > 0.05). There were also no significant differences among the tube currents for the specificity values (p > 0.05); however, the specificity differed significantly between the "with implant" and "without implant" conditions, within the same MAR condition and tube current (p < 0.05). Specificity was significantly lower when the implant was present (p < 0.05). CONCLUSION: The presence of a zirconium implant impairs the diagnosis of VRF in teeth adjacent to the artifact-generator material. Neither the tube current nor the MAR tool is effective in improving this diagnostic task. Therefore, in this clinical scenario, the use of the lowest tube current (4 mA), without MAR activation, is recommended. CLINICAL RELEVANCE: Considering that the tube current is one of the main factors that influence the radiation dose and image quality in CBCT, and that metal artifacts negatively influence the diagnosis of VRF in areas adjacent to the artifact-generator material, it is important to evaluate the effect of this energetic parameter in the diagnosis of VRF in teeth adjacent to zirconium implants.


Asunto(s)
Implantes Dentales , Tomografía Computarizada de Haz Cónico Espiral , Fracturas de los Dientes , Artefactos , Tomografía Computarizada de Haz Cónico , Humanos , Fracturas de los Dientes/diagnóstico por imagen , Raíz del Diente/diagnóstico por imagen , Circonio
17.
Leg Med (Tokyo) ; 47: 101743, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32659706

RESUMEN

The aim in this study was to evaluate the influence of skeletal class, facial type, and sex on soft tissue thickness (STT) of the craniofacial midline in a Brazilian subpopulation. Thus, 121 cone beam computed tomography (CBCT) scans (54 males and 67 females, age 21 to 40 yrs) composed the study sample. Patients were classified according to skeletal class (class I, II, and III) and facial type (brachycephalic, mesocephalic, and dolichocephalic), and STT was measured (mm) in 10 landmarks in the craniofacial midline for each CBCT scan. Multivariate analysis of covariance evaluated facial STT with regard to multiple independent variables (sex, age - covariate, facial type, and skeletal class). TEM and rTEM assessed the intra-examiner agreement. STT was significantly greater in males than in females for all regions measured (p < 0.05), except for the pogonion-pogonion' landmark (p>0.05). In general, class III individuals had significantly thicker soft tissue in the maxilla - subspinale-subnasale', prosthion-labrale superius', and incision-stomion' regions, while class II subjects had thicker soft tissue in the infradentale-labrale inferius' mandibular landmark (p < 0.05). Regarding facial type, dolichocephalic individuals showed significantly thicker soft tissue in the supramentale-supramentale' mandibular landmark, whereas brachycephalic subjects had thicker soft tissue in maxillary regions - prosthion-labrale superius' and incision-stomion' (p < 0.05). rTEM values were below 5% for most landmarks, and all TEM values were below 1 mm. Skeletal class and facial type influence STT, showing a soft tissue compensation, with deeper soft tissue in areas with lower skeletal development, and/or where bone is positioned more posteriorly.


Asunto(s)
Cefalometría/métodos , Tomografía Computarizada de Haz Cónico/métodos , Tejido Conectivo/anatomía & histología , Tejido Conectivo/diagnóstico por imagen , Cara/anatomía & histología , Cara/diagnóstico por imagen , Huesos Faciales/anatomía & histología , Huesos Faciales/diagnóstico por imagen , Antropología Forense/métodos , Odontología Forense/métodos , Adulto , Brasil , Femenino , Humanos , Masculino , Caracteres Sexuales , Adulto Joven
18.
Toxins (Basel) ; 12(6)2020 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-32549196

RESUMEN

This study assessed the safety and efficacy of three different doses of BoNT-A for persistent myofascial pain (MFP). One hundred female subjects were randomly assigned into five groups (n = 20): oral appliance (OA), saline solution (SS) and three BoNT-A groups with different doses. Pain intensity and pressure pain threshold were evaluated up to 24 weeks after treatment. Adverse effects related to muscle contraction, masticatory performance, muscle thickness and mandibular bone volume were also assessed. Changes over time were compared within and between groups. The "nparLD" package and Wilcoxon signed-rank test were used to analyze the data. BoNT-A reduced pain intensity (p < 0.0001) and increased pressure pain threshold (p < 0.0001) for up to 24 weeks compared to the placebo. No differences were found between BoNT-A and OA at the last follow-up. A transient decline in masticatory performance (p < 0.05) and muscle contraction (p < 0.0001), and a decrease in muscle thickness (p < 0.05) and coronoid and condylar process bone volume (p < 0.05) were found as dose-related adverse effects of BoNT-A. Regardless of the dose, BoNT-A was as effective as OA on MFP. Notwithstanding, due to BoNT-A dose-related adverse effects, we suggest the use of low doses of BoNT-A in MFP patients that do not benefit from conservative treatments.


Asunto(s)
Analgésicos/administración & dosificación , Toxinas Botulínicas Tipo A/administración & dosificación , Dolor Facial/tratamiento farmacológico , Umbral del Dolor/efectos de los fármacos , Adulto , Analgésicos/efectos adversos , Toxinas Botulínicas Tipo A/efectos adversos , Brasil , Relación Dosis-Respuesta a Droga , Dolor Facial/diagnóstico , Dolor Facial/fisiopatología , Femenino , Humanos , Masticación/efectos de los fármacos , Dimensión del Dolor , Factores de Tiempo , Resultado del Tratamiento
19.
Clin Oral Investig ; 24(11): 4069-4076, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32333179

RESUMEN

OBJECTIVES: To compare the pulp volume of individuals with altered and normal systemic blood pressure (BP) in order to verify if high BP promotes dimensional modifications in the pulp space. MATERIALS AND METHODS: Cone beam computed tomography scans of 91 patients (49 females and 42 males, mean age 31.7 ± 6.38 years) who had a healthy maxillary canine were selected. Values of arterial BP measured at two dental visits were used to classify the sample as normal BP (< 130 × 80 mmHg) and altered BP (≥ 130 × 80 mmHg); 49 patients had normal BP and 42 had altered BP. One oral radiologist evaluated each patient's pulp and tooth volumes, using semi-automatic segmentation, and the tooth length. Data were submitted to Student's t test and logistic regression, with a significance level of 5% (p < 0.05). RESULTS: Pulp volume (p = 0.0027), pulp volume/tooth volume (p = 0.0013), and pulp volume/tooth length (p = 0.0007) ratios were greater in the altered BP group. Conversely, there was no difference in tooth volume between the groups (p = 0.0697). A logistic regression model (p = 0.0002) using pulp volume and age enabled the development of a formula for predicting altered BP, with 68% accuracy. CONCLUSIONS: Individuals with altered systemic BP have greater pulp volumes than those with normal BP. The formula developed in this study may indicate the presence of altered BP. CLINICAL RELEVANCE: As arterial hypertension is a silent disease that produces no warning signs or symptoms, identification of modifications in the pulp volume in cone beam computed tomography scans may be an adjuvant sign of the diagnosis of this disease.


Asunto(s)
Determinación de la Edad por los Dientes , Hipertensión , Tomografía Computarizada de Haz Cónico Espiral , Adulto , Presión Sanguínea , Tomografía Computarizada de Haz Cónico , Pulpa Dental/diagnóstico por imagen , Femenino , Humanos , Hipertensión/diagnóstico por imagen , Masculino
20.
Dentomaxillofac Radiol ; 49(4): 20190384, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32027521

RESUMEN

OBJECTIVES: To access the influence of the addition of a lead foil to intraoral digital radiographic receptors on image contrast and approximal caries lesions diagnosis. METHODS: 40 posterior teeth were distributed in silicone phantoms composed of two premolars, two molars and a non-test canine. Radiographic images of the phantoms were obtained with and without the incorporation of a lead foil, using the Digora Optime and Digora Toto systems. Four observers scored the images for the presence of caries lesions, using a 5-point scale. Images of an aluminum step wedge were acquired with and without the incorporation of a lead foil. Gray values and standard deviation of gray values were calculated in different thickness of the step wedge and, then, contrast variation was calculated. RESULTS: Presence of a lead foil did not influence caries lesions diagnostic values, regardless of the type of digital system (p > 0.05). In general, the objective analysis was not influenced by the presence of a lead foil in any of the tested systems (p > 0.05). However, Digora Toto images showed greater gray values, lower standard deviation of gray values and lower contrast variation, regardless of the presence of the lead foil (p < 0.05). CONCLUSIONS: The addition of a lead foil to intraoral digital receptors did not influence image contrast nor caries lesions diagnosis.


Asunto(s)
Caries Dental/diagnóstico por imagen , Radiografía Dental Digital , Diente Premolar/diagnóstico por imagen , Humanos , Diente Molar , Variaciones Dependientes del Observador , Fantasmas de Imagen , Curva ROC
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...